# Magnetic Flux Converter > Convert between magnetic flux units: weber, maxwell, volt-second, and more **Category:** Conversion **Keywords:** magnetic flux, weber, maxwell, volt-second, electromagnet, physics **URL:** https://complete.tools/magnetic-flux-converter ## How it calculates The Magnetic Flux Converter uses the weber (Wb) as the reference base unit for all calculations. Each unit has a defined conversion factor relative to the weber, and the tool performs a two-step conversion process: first converting the input value to webers, then converting from webers to all target units. The fundamental conversion formula is: Value in Target Unit = (Input Value / Source Unit Factor) * Target Unit Factor The conversion factors used are based on established physical relationships: - 1 Weber (Wb) = 1 (base unit) - 1 Milliweber (mWb) = 0.001 Wb, so factor = 1000 - 1 Microweber (uWb) = 1e-6 Wb, so factor = 1,000,000 - 1 Nanoweber (nWb) = 1e-9 Wb, so factor = 1,000,000,000 - 1 Kiloweber (kWb) = 1000 Wb, so factor = 0.001 - 1 Maxwell (Mx) = 1e-8 Wb, so factor = 100,000,000 - 1 Volt-second (V·s) = 1 Wb (by definition of the weber) - 1 Tesla square meter (T·m2) = 1 Wb (since Wb = T * m2) - 1 Gauss square centimeter (G·cm2) = 1e-8 Wb - 1 Magnetic flux quantum (Phi0) = 2.067833848e-15 Wb (fundamental constant h/2e) For example, to convert 5 milliwebers to maxwells: First convert to webers (5 / 1000 = 0.005 Wb), then multiply by the maxwell factor (0.005 * 1e8 = 500,000 Mx). ## Who should use this 1. Electrical engineers designing transformers, inductors, and electromagnetic devices need to convert between SI and CGS units when referencing older technical literature or international specifications. 2. Physics students studying electromagnetic induction and Faraday's law benefit from seeing how magnetic flux values translate across different unit systems used in textbooks and laboratory equipment. 3. Researchers in superconductivity and quantum computing work with magnetic flux quanta when analyzing Josephson junctions and SQUID magnetometers, requiring precise conversions to fundamental units. 4. Magnetic sensor engineers and calibration technicians who work with gaussmeters and teslameters need to convert readings between different measurement standards. 5. Power systems engineers analyzing transformer cores and magnetic circuits often encounter specifications in various unit systems depending on the equipment manufacturer's country of origin. ## Worked examples Example 1: A transformer specification lists a maximum core flux of 50 milliwebers. To verify this against a CGS-based design manual, convert to maxwells: 50 mWb to Wb: 50 / 1000 = 0.05 Wb 0.05 Wb to Mx: 0.05 * 1e8 = 5,000,000 Mx (or 5 megamaxwells) Example 2: A SQUID magnetometer measures flux in units of Phi0 (magnetic flux quantum). If a measurement reads 1,000,000 Phi0, what is this in webers? 1,000,000 Phi0 to Wb: 1,000,000 * 2.067833848e-15 = 2.068e-9 Wb This equals approximately 2.07 nanowebers. Example 3: An inductor datasheet specifies flux linkage as 0.5 volt-seconds at rated current. Express this in microwebers: Since 1 V·s = 1 Wb exactly: 0.5 V·s = 0.5 Wb 0.5 Wb to uWb: 0.5 * 1e6 = 500,000 uWb Example 4: A magnetic circuit analysis gives a core flux of 2.5 T·m2. Convert to milliwebers and maxwells: Since T·m2 = Wb: 2.5 T·m2 = 2.5 Wb 2.5 Wb to mWb: 2.5 * 1000 = 2,500 mWb 2.5 Wb to Mx: 2.5 * 1e8 = 250,000,000 Mx ## Understanding magnetic flux units Magnetic flux quantifies the total magnetic field passing through a surface. In SI units, it is measured in webers, where one weber equals one tesla of magnetic flux density passing through one square meter of area. The weber is named after German physicist Wilhelm Eduard Weber, who made significant contributions to the study of magnetism in the 19th century. The CGS (centimeter-gram-second) system uses the maxwell as its unit of magnetic flux, named after James Clerk Maxwell. One maxwell represents one gauss of flux density through one square centimeter, making it much smaller than the weber: exactly 10^-8 webers. Despite being largely replaced by SI units in modern physics, the maxwell and gauss still appear in older literature and some specialized applications. The volt-second equivalence comes directly from Faraday's law of electromagnetic induction, which states that the induced electromotive force (EMF) equals the rate of change of magnetic flux. Since EMF is measured in volts and time in seconds, flux has dimensions of volt-seconds. The magnetic flux quantum (Phi0) holds special significance in quantum mechanics. It represents the smallest amount of magnetic flux that can thread a superconducting loop, approximately 2.07 x 10^-15 webers. This quantization of flux is fundamental to understanding superconducting quantum interference devices (SQUIDs) and has applications in quantum computing. ## Limitations The Magnetic Flux Converter has several limitations users should be aware of. First, the tool performs unit conversions only and does not calculate magnetic flux from field strength and area inputs. Users must already know their flux value in some unit to use the converter. Second, while the magnetic flux quantum value uses the CODATA recommended value (2.067833848 x 10^-15 Wb), this is a measured fundamental constant with some experimental uncertainty. For ultra-precise quantum metrology applications, users should verify they are using the most current accepted value. Third, the converter does not distinguish between different regional or historical definitions of units. For instance, some older texts may use slightly different values for the maxwell-to-weber conversion. The tool uses the standard modern definitions. Fourth, extremely large or small values may display in scientific notation, which is necessary for readability but may require users to interpret exponential format. Additionally, floating-point arithmetic limitations mean that conversions involving very large numbers (beyond 10^15) or very small numbers (below 10^-15) may have minor rounding errors. Finally, this tool converts scalar magnetic flux values only. It does not handle vector magnetic flux or flux density (B-field) conversions, which would require separate tools. ## FAQs **Q:** What is the difference between magnetic flux and magnetic flux density? **A:** Magnetic flux (measured in webers) is the total magnetic field passing through a surface, while magnetic flux density or B-field (measured in tesla) is the flux per unit area. Flux equals flux density multiplied by the perpendicular area: Phi = B * A. **Q:** Why are volt-second and tesla square meter both equal to one weber? **A:** These equivalences come from fundamental electromagnetic definitions. From Faraday's law, flux change over time produces voltage (V = dPhi/dt), so flux has units of V·s. Since B-field is in tesla and flux is B times area in m2, we get T·m2 = Wb. **Q:** When would I use maxwells instead of webers? **A:** Maxwells are primarily used when working with CGS-based literature, older engineering references, or when interfacing with legacy measurement equipment calibrated in CGS units. Modern international standards use webers. **Q:** What is the magnetic flux quantum used for? **A:** The magnetic flux quantum (Phi0) is essential in superconductor physics and quantum computing. It represents the smallest discrete unit of flux in superconducting systems and is used to characterize SQUID sensors, Josephson junctions, and flux qubits. **Q:** How do I convert between gauss and tesla if this tool only handles flux? **A:** This tool converts magnetic flux units (Wb, Mx), not flux density units (T, G). For flux density conversions, note that 1 tesla = 10,000 gauss. A separate magnetic flux density converter would handle those units directly. **Q:** Can I use this for AC magnetic flux calculations? **A:** Yes, the converter works for instantaneous flux values in AC systems. However, for RMS or peak-to-peak flux calculations in AC circuits, you would need to determine those values separately before converting units. --- *Generated from [complete.tools/magnetic-flux-converter](https://complete.tools/magnetic-flux-converter)*